Lighthouse Inspection Reports Database
Tree Point Light Station - 1919
Fog Signal Equipment
Report Sections:
Premises | Lantern and Fixtures | Ventilators and Watchroom | Illuminating Apparatus | Closets and Storerooms
Fog Signal General | Fog Signal Equipment | Dwelling | Asst. Keepers Dwellings | Water | Healthfulness
Lighthouse Access | Station Boat Info | Tools and Accessories | Light Vessel Specific | Inspection Reports
Home | About Us | Magazine | Membership | Lighthouse Passports | Tours | Lightship | Resources | Store | Contact Us | Site Map
© 2006 United States Lighthouse Society · 244 Kearny Street 5th Floor, San Francisco CA 94108 · ph. 415.362.7255
Fog Signal Kind:
Internal Combustion Kind:
Internal Comb Manufacturer:
Internal Comb Date:
Internal Comb Size:
Internal Comb Horsepower:
Internal Comb Fuel:
Internal Comb Starter:
Internal Comb compressor:
Compressor Maker:
Compressor seat:
Compressor Machinery:
Compressor diameter:
Compressor stroke:
Compressor rpms:
Character of air inlet:
Kind of Unloader:
Diam of Delivery Pipe:
Hornsby Akroyd Kerosene oil engine
De La Vergne Machine Co.
1903
11" x 15"
13 HP
Kerosene
By heating with torch.
Double acting
Herron & Bury High service.
Same bed; geared
10"
8"
Herron & Burry, Erie, Pa.
2"
Internal Combustion Signal
Siren:
Siren diameter:
Siren built date:
Siren Manufacturer:
Siren ports:
Siren revolutions:
Siren governor:
Siren condition:
Cylindrical
6"
1903
3rd Dist. Tomkinsville, NY
20 3/32" x 2.75"
sectional ring
Good
Siren Signal
Number:
Diameter:
Height:
Capacity Cubic Feet:
Pressure in each:
Make of Reducing Valve:
Remarks:
1
40"
18 feet
157 cu. ft.
70 lbs.
Air Receiver