Steam Boiler:
Kind:
Tube:
Dimensions:
Length:
Diameter:
Tube desc:
Steam tube diameter:
Steam Furnace Kind:
Furnace length:
Furnace width:
Furnace height:
Steam heat surface:
Steam grate surface:
Number of grate bars:
Kind of grate bars:
Steam fuel:
Steam safety valve:
Steam max pressure:
Steam working pressure:
Steam diam of smokestack:
Smokestack height:
Drum dimension:
Steam Drum diameter:
Steam covering:
Steam boiler condition:
Steam boiler built:
Where built:
Manufacturer:
Steam heater:
Kind:
Size:
Heater time affect:
Steam Engine kind:
Steam Engine revolution:
Steam Engine cyl diameter:
Steam Engine piston stroke:
Steam Engine pipe size:
Steam Engine when built:
Steam Engine where built:
Manufacturer:
Steam
Marine, open bottom
Flue tube
height 7' 5"
6' 6"
width 4' 9"
102 - 5' 1 1/4"
2.5"
part of boiler
5'
4' 1 1/4"
1' 6"
393-95
20 sq. ft.
18
2 bar spade ends, cast iron
bituminous coal & wood
2.5"
135#
90#
24"
38' 8"
3' 9"
36"
Felt covered with canvas & lined with asbestos
good
1895
Dayton, OH
Miami Valley Boiler Co.
No. Automatic signal
Steam Signal
Whistle diameter:
Whistle height:
Whistle orifice:
Whistle tone:
Whistle chime:
10"
16"
2 3/4"
single tone
Whistle Signal