Fog Signal Kind:
Internal Combustion Kind:
Internal Comb Manufacturer:
Internal Comb Date:
Internal Comb Size:
Internal Comb Horsepower:
Internal Comb Fuel:
Internal Comb Starter:
Internal Comb compressor:
Compressor Maker:
Compressor seat:
Compressor Machinery:
Compressor diameter:
Compressor stroke:
Compressor rpms:
Character of air inlet:
Kind of Unloader:
Diam of Delivery Pipe:
Charter-Mietz Vertical Oil Engine & Compressor.
Charter Gas Engine Co., Sterling, Ill.
July 1926
7" x 8"
9
Diesel oil
By heating iron ball using blow-torch
Vertical; direct connected single acting.
Charter Gas Eng. Co.
Same bed, direct connected.
7"
8"
400 rpm
Disc 4.5"
Spring compression
2"
Internal Combustion Signal
Number:
Diameter:
Height:
Capacity Cubic Feet:
Pressure in each:
Make of Reducing Valve:
Remarks:
2
3.5 feet
7' 10"
76 feet
30 lbs.
None.
Air Receiver
Daboll:
Daboll reed:
Daboll length:
Daboll breadth:
Daboll base thickness:
Daboll tip thickness:
3rd class
8-7/16"
2.25"
3/8"
3/16"
Daboll Signal