Steam Boiler:

 

Kind:

 

Tube:

 

Dimensions:

 

Length:

 

Diameter:

 

Tube desc:

 

Steam tube diameter:

 

Steam Furnace Kind:

 

Furnace length:

 

Furnace width:

 

Furnace height:

 

Steam heat surface:

 

Steam grate surface:

 

Number of grate bars:

 

Kind of grate bars:

 

Steam fuel:

 

Steam safety valve:

 

Steam max pressure:

 

Steam working pressure:

 

Steam diam of smokestack:

 

Smokestack height:

 

Drum dimension:

 

Steam Drum diameter:

 

Steam covering:

 

Steam boiler condition:

 

Steam boiler built:

 

Where built:

 

Manufacturer:

 

Steam heater:

 

Kind:

 

Size:

 

Heater time affect:

 

Steam Engine kind:

 

Steam Engine revolution:

 

Steam Engine cyl diameter:

 

Steam Engine piston stroke:

 

Steam Engine pipe size:

 

Steam Engine when built:

 

Steam Engine where built:

 

Manufacturer:

30 hp

 

horizontal

 

Flue tube

 

 

 

12'

 

42"

 

41 tubes 12' long

 

2"

 

brick

 

4'

 

4'

 

 

 

430 sq. ft.

 

16 sq. ft.

 

20

 

double

 

crude oil

 

2.5" lever & ball

 

70 lbs at present

 

60 lbs

 

brick stack, 20" inside

 

40'

 

length 4' 6"

 

2' 6"

 

none

 

Both boilers need replacing

 

1890 & 1892

 

San Francisco, CA

 

Moynihan & Co.

 

 

 

 

 

 

 

 

 

Horizontal slide valve

 

 

 

4"

 

8"

 

1"

 

no date

 

no name of place

 

no name

Steam Signal

Whistle diameter:

 

Whistle height:

 

Whistle orifice:

 

Whistle tone:

 

Whistle chime:

12"

 

2' 8"

 

2.5"

 

single

Whistle Signal