Fog Signal Kind:
Internal Combustion Kind:
Internal Comb Manufacturer:
Internal Comb Date:
Internal Comb Size:
Internal Comb Horsepower:
Internal Comb Fuel:
Internal Comb Starter:
Internal Comb compressor:
Compressor Maker:
Compressor seat:
Compressor Machinery:
Compressor diameter:
Compressor stroke:
Compressor rpms:
Character of air inlet:
Kind of Unloader:
Diam of Delivery Pipe:
4 cyl Dir. conn'd Waukesha Oil Engine water cooled
Waukesha Motor Co. Serial No. 416501 (Model XBKH-48A)
3 3/4" x 4 3/4"
22.4 HP
Diesel Oil
Anderson Ind. Delco Remy Model 1107902 Serial 7E12
3-cyl air cooled
Ingersoll Rand Co. serial No. 4OT-3341
5" x 4" 80 cu ft free air per min at 40# pressure
Internal Combustion Signal
Engine Generators
Storage Batteries
Engine Kind:
Engine Manufacturer:
Engine Serial Number:
Number of Cylinders (Engine):
Engine Cylinder Size:
Engine HP:
Fuel:
Starter:
Date Installed:
Generator Kind:
Generator Maker:
Generator Serial Number:
Generator Cylinder Size:
Air Capacity:
Number of Cylinders (Generator):
Direct connected Full diesel 4-cycle
Fairbanks Morse Co.
Model 36A4.5DE
1
4.5" x 5"
10 HP
Diesel Oil
Automatic when radiobeacon starts
August, 1937
5 kw 110v DC
Fairbanks Morse Co.
X59301
(no load 125V)
(Full load 118V)
Kind:
Manufacturer:
Number of Cells:
Cells per Tray:
Capacity:
Location:
Date Installed:
Lead - acid - SO-98041
Philadelphia Storage Battery Co., PA
56PW015
14
214 amp. hr
Battery room basement of tower
June 28, 1932; Fully charged SP. GR. 1225; Charge rate @ finish 11 amps.
Number:
Diameter:
Height:
Capacity Cubic Feet:
Pressure in each:
Make of Reducing Valve:
Remarks:
3 tanks
42"
7'
67 cu ft. each