Lantern:

 

Illuminating Apparatus:

 

Service Lamp:

 

Oil:

 

Service Lamp Burner:

 

Service Lamp Burner Level:

 

Plate Glass:

 

Lens Cover:
 

 

Lantern Curtains:

 

Carillon or Alarm Bell:

 

Rod Lamp:

 

Dwelling:

 

Stairway and Landing:

 

Inside of tower:

 

Glazing of Dwelling:

 

Improvements Needed:

 

Outhouses:

 

Boathouse:

 

Grounds:

Lighthouse Inspection Reports Database

Havre de Grace Light Station - 1867

Inspection Reports Page 1 of 2

In good condition

 

Lens was in good condition & perfectly clean in all its parts.

 

In good condition in all respects.

 

Specimen examined & found to be clear & clean.

 

In good condition in all respects.

 

was level.

 

Was clean & in perfectly good condition.

 

It was on; & clean, made of toweling & is kept in lantern room when not in use. Supplied a new cover here.

 

none

 

none

 

none

 

Very good

 

In very good order.

 

Was whitewashed newly put on, in good condition.

 

very good

 

do not know of any

 

in good condition

 

none

 

In very good condition. They have the appearance of neatness & care.

Report Sections:

Premises | Lantern and Fixtures | Ventilators and Watchroom | Illuminating Apparatus | Closets and Storerooms

 

Fog Signal General | Fog Signal Equipment | Dwelling | Asst. Keepers Dwellings | Water | Healthfulness

 

Lighthouse Access | Station Boat Info | Tools and Accessories | Light Vessel Specific | Inspection Reports

 

Supplemental Reports

Condition of:

Home | About Us | Magazine | Membership | Lighthouse Passports  | Tours | Lightship | Resources | Store | Contact Us | Site Map

© 2006 United States Lighthouse Society · 244 Kearny Street 5th Floor, San Francisco CA 94108 · ph. 415.362.7255

Lens:

 

Lantern and Trap Doors:

 

Watch or Trimming Room:

 

Lucernes or Matches:
 

 

Heater:

 

Ventilation:

 

Dome:

It's not allowed to touch the lens improperly.

 

yes

 

There were none of the above named articles lying about.

 

There were some matches found in the lantern room. Keeper's attention was called to the impropriety of having them there.

 

There is no heater

 

Keeper understands use of ventilators & how to air the bldg.

 

They were so painted. Lightning conductor was in good order, & led into the ground.

Equipment Care

Does Keeper Understand the Use and Care of:

Oil Room:

 

Oil Carriers:

In good condition, ventilation good.

 

In good condition & properly arranged.

Oil Room

Condition of:

Number of:

100 gallon oil:

 

50 gallon oil:

 

Small butts for Waste Oil:

 

Dripping Buckets:

 

Oil Tanks:

 

 

2

 

 

 

2

 

2 holding 100 gallons.

Oil butts made according to regulation:

 

Oil butt covers:
 

 

Drip Bucket Placement:

 

Oil Butt Platform:

 

Empty Oil Butts:

They are so made.

 

Gutters were filled w/ refuse oil & air cocks closed. Keeper understands use of covers & air cocks.

 

yes

 

Placed upon masonry w/ raised platform (of plank) between.

 

There were no empty oil butts.

General Information: