Lantern:

 

Illuminating Apparatus:

 

Service Lamp:

 

Oil:

 

Service Lamp Burner:

 

Service Lamp Burner Level:

 

Plate Glass:

 

Lens Cover:

 

Lantern Curtains:

 

Carillon or Alarm Bell:

 

Rod Lamp:

 

Dwelling:

 

Stairway and Landing:

 

Inside of tower:

 

Glazing of Dwelling:

 

Improvements Needed:

 

Outhouses:

 

Boathouse:

 

Grounds:

Lighthouse Inspection Reports Database

Fog Point Light Station - 1867

Inspection Reports Page 1 of 2

In perfect order - new made & put up.

 

Clean inside & out & in very good condition.

 

Clean inside & out; the glass chimney free from dirt of every kind.

 

Specimen of oil examined & found to be clear & clean. It had been filtered.

 

Free from gummy or burnt oil. Clean with wick trimmed according to printed instructions.

 

Found to be level.

 

Perfectly clean in every respect.

 

It was on lens; clean; made of ticking & is kept in lantern room when not in use.

 

none

 

none

 

none

 

Dwelling was in good condition & is kept remarkably clean.

 

Very clean; not painted.

 

 

 

In very good condition.

 

Repairs to fencing are needed.

 

In good condition

 

 

 

In good condition

Report Sections:

Premises | Lantern and Fixtures | Ventilators and Watchroom | Illuminating Apparatus | Closets and Storerooms

 

Fog Signal General | Fog Signal Equipment | Dwelling | Asst. Keepers Dwellings | Water | Healthfulness

 

Lighthouse Access | Station Boat Info | Tools and Accessories | Light Vessel Specific | Inspection Reports

 

Supplemental Reports

Condition of:

Home | About Us | Magazine | Membership | Lighthouse Passports  | Tours | Lightship | Resources | Store | Contact Us | Site Map

© 2006 United States Lighthouse Society · 244 Kearny Street 5th Floor, San Francisco CA 94108 · ph. 415.362.7255

Lens:

 

Lantern and Trap Doors:

 

Watch or Trimming Room:

 

Lucernes or Matches:

 

Heater:

 

Ventilation:

 

Dome:

It is not permitted to touch the lens improperly.

 

yes

 

None of these articles were to be seen.

 

None of these articles were to be seen.

 

No heater

 

Keeper understands use of ventilators & how to air the bldg.

 

They were so painted & in good order. Lightning conductor was in good condition & led into the ground.

Equipment Care

Does Keeper Understand the Use and Care of:

Oil Room:

 

Oil Carriers:

Clean; well ventilated, & no waste of oil on the floor.

 

There was a small supply at station, but everything on hand was in order.

Oil Room

Condition of:

Number of:

100 gallon oil:

 

50 gallon oil:

 

Small butts for Waste Oil:

 

Dripping Buckets:

 

Oil Tanks:

 

 

2

 

1 - of 5 gallons

 

2

 

3, holding 105 gallons.

Oil butts made according to regulation:

 

Oil butt covers:

 

Drip Bucket Placement:

 

Oil Butt Platform:

 

Empty Oil Butts:

They are so made.

 

Gutters were filled & covers on & air cocks closed.

 

yes

 

Are placed on a raised platform

 

No empty oil butts at the station.

General Information: