Lantern:
Illuminating Apparatus:
Service Lamp:
Oil:
Service Lamp Burner:
Service Lamp Burner Level:
Plate Glass:
Lens Cover:
Lantern Curtains:
Carillon or Alarm Bell:
Rod Lamp:
Dwelling:
Stairway and Landing:
Inside of tower:
Glazing of Dwelling:
Improvements Needed:
Outhouses:
Boathouse:
Grounds:
Lighthouse Inspection Reports Database
Bowlers Rock Light Station
Inspection Reports Page 1 of 2
Very good condition.
Clean & in good condition.
In good condition in every respect.
Oil examined & found to be free from all dirt motes etc & had not been filtered.
Free from all gummy or burnt oil, the wicks are well trimmed.
It was found to be level.
Very clean & free from all scratches, stains or dirt.
Cover was on; clean; made of linen ticking; kept hung up in the lantern room when not in use.
2 sets; clean; & in good condition; put up & taken down at proper times.
None
There is a Rod lamp in very clean & good condition; trimmed ready for use.
Clean & painted.
Very good.
In very good condition.
The stove needs a new grate, & soapstone for sides & back.
Report Sections:
Premises | Lantern and Fixtures | Ventilators and Watchroom | Illuminating Apparatus | Closets and Storerooms
Fog Signal General | Fog Signal Equipment | Dwelling | Asst. Keepers Dwellings | Water | Healthfulness
Lighthouse Access | Station Boat Info | Tools and Accessories | Light Vessel Specific | Inspection Reports
Supplemental Reports
Condition of:
Home | About Us | Magazine | Membership | Lighthouse Passports | Expeditions | Lightship | Resources | Store | Contact Us | Store | Site Map
© 2006 United States Lighthouse Society · 244 Kearny Street 5th Floor, San Francisco CA 94108 · ph. 415.362.7255
Lens:
Lantern and Trap Doors:
Watch or Trimming Room:
Lucernes or Matches:
Heater:
Ventilation:
Dome:
Lens is never touched improperly.
They fit properly
None of these articles are seen at the time of inspection.
There were none of the above mentioned articles visible in the rooms.
The Keeper understands the use of the heater
Keeper understands the use of the ventilators & how to air the bldg.
They were painted according to instructions. The lightning conductor was in good order.
Equipment Care
Does Keeper Understand the Use and Care of:
Oil Room:
Oil Carriers:
Clean, well ventilated, no appearance of waste.
Good condition & properly arranged.
Oil Room
Condition of:
Number of:
100 gallon oil:
50 gallon oil:
Small butts for Waste Oil:
Dripping Buckets:
Oil Tanks:
none
2
1
2 pans
3 holding 125 gallons.
Oil butts made according to regulation:
Oil butt covers:
Drip Bucket Placement:
Oil Butt Platform:
Empty Oil Butts:
They are so made
The gutters were so filled & covers on. Keeper understands the use of the covers and air cocks.
There were 2 pans placed under each butt.
They are placed upon a raised platform of wood.
None
General Information: